<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Cosmetics Archives - Quantek Instruments</title>
	<atom:link href="https://quantekinstruments.maxdroplet8.maxburst.dev/product-tag/cosmetics/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Quantek Instruments provides oxygen and carbon dioxide analyzers and solutions to food, pharmaceutical, research, educational, and government institutions worldwide.</description>
	<lastBuildDate>Tue, 06 May 2025 18:38:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://quantekinstruments.maxdroplet8.maxburst.dev/wp-content/uploads/2021/10/cropped-512x512-1-1-32x32.png</url>
	<title>Cosmetics Archives - Quantek Instruments</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Q42 Rackmount-2U O2 / CO2 Analyzer</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/q42-rackmount-2u-o2-co2-analyzer/</link>
		
		<dc:creator><![CDATA[Scott Mckeown]]></dc:creator>
		<pubDate>Thu, 22 Aug 2024 18:14:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.quantekinstruments.com/?post_type=product&#038;p=4222</guid>

					<description><![CDATA[The Quantek Model Q42 is our next generation rackmount O2 / CO2 analyzer. Use it for process systems, inline testing, along with many other types of applications.

This microprocessor-controlled instrument features onboard data collection, a TFT full color screen, built in analog output (0-5V), and EasyCal calibration using the touchpad.  Additionally, it can be outfitted with options such as a sample pump, or a 12-hour runtime internal battery.

Readings can be exported to USB thumb drive as CSV file for further processing. The Q42 comes with a power supply, thumb drive, and consumable accessories.]]></description>
										<content:encoded><![CDATA[<p><strong>NEXT GENERATION TECHNOLOGY</strong></p>
<p>Introducing the Q42, the next generation of Quantek analyzers. This analyzer utilizes the latest in microprocessor-based sampling, and comes equipped with an advanced TFT display, smart charging, onboard data collection, advanced pump functions, and EasyCal calibration controls.</p>
<p><strong>LONG LIFE, STABLE SENSORS</strong></p>
<p>The Model Q42 incorporates the latest fast response O2 and CO2 sensors, which allows results to be obtained in 15-25 seconds for rapid spot checks. The oxygen sensor is rated for 5 years of life, which is far better than the competition. Other analyzers utilize cheap oxygen sensors which may last 18-24 months.</p>
<p><strong>EASY SAMPLING METHOD</strong></p>
<p>The Q42 series sample inlet and outlet are located on the rear panel for ease of access.  By default, both fittings are 1/8” stainless steel Swagelok.  Other inlet/outlet configurations are available upon request.  Some examples include standard luer fittings, ¼” Swagelok fittings, or a sample probe.  We can recommend or customize fittings to give the most seamless sampling experience for whatever system you may have.</p>
<p><strong>USER FRIENDLY, ACCESSIBLE CONTROLS</strong></p>
<p>Navigate the user-friendly interface, and you can adjust the oxygen calibration, pump time, CO2 calibration, and other parameters on the fly. There’s no need to reboot and no need to warmup – it’s as easy as it gets.</p>
<p><strong>ABOUT THE SENSORS</strong></p>
<p>The infrared CO2 sensor utilizes NDIR technology for maximum stability and has a theoretically unlimited lifespan.  It has no moving parts, no consumables, and is housed in a compact optical cell. The sensor responds to CO2 only.<br />
The electrochemical O2 sensor life is typically 4-5 years, unlike other analyzers with an electrochemical sensor that last 1-2 years. When required, replacement is easy and inexpensive.  Both sensors are unaffected by high levels of background gases such as nitrogen.</p>
<p><strong>WARRANTY STATEMENT</strong></p>
<p>The Model Q42 is backed up with a two-year warranty, twice the industry standard.<br />
Our service team responds quickly to the repair needs of our customers, and repairs and calibrations are conducted in our advanced facility in Massachusetts.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Q41 Rackmount-2U CO2 Analyzer</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/q41-rackmount-2u-co2-analyzer/</link>
		
		<dc:creator><![CDATA[Scott Mckeown]]></dc:creator>
		<pubDate>Thu, 22 Aug 2024 17:53:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.quantekinstruments.com/?post_type=product&#038;p=4221</guid>

					<description><![CDATA[The Quantek Model Q41 is our next generation portable CO2 analyzer. Use it for process systems, inline testing, along with many other types of applications.

This microprocessor-controlled instrument features onboard data collection, a TFT full color screen, built in analog output (0-5V), and EasyCal calibration using the touchpad.  Additionally, it can be outfitted with options such as a sample pump, or a 12-hour runtime internal battery.

Readings can be exported to USB thumb drive as CSV file for further processing. The Q41 comes with a power supply, thumb drive, and consumable accessories.]]></description>
										<content:encoded><![CDATA[<p><strong>NEXT GENERATION TECHNOLOGY</strong></p>
<p>Introducing the Q41, the next generation of Quantek analyzers. This analyzer utilizes the latest in microprocessor based sampling, and comes equipped with an advanced TFT display, smart charging, onboard data collection, advanced pump functions, and EasyCal calibration controls.</p>
<p><strong>LONG LIFE, STABLE SENSORS</strong></p>
<p>The Model Q41 incorporates the latest fast response CO2 sensor, which allows results to be obtained in 15-25 seconds for rapid spot checks, or run continuously for process monitoring.  The CO2 detector is a dual wavelength NDIR sensor with a theoretically unlimited lifespan.</p>
<p><strong>EASY SAMPLING METHOD</strong></p>
<p>The Q41 series sample inlet and outlet are located on the rear panel for ease of access.  By default, both fittings are 1/8” stainless steel Swagelok.  Other inlet/outlet configurations are available upon request.  Some examples include standard luer fittings, ¼” Swagelok fittings, or a sample probe.  We can recommend or customize fittings to give the most seamless sampling experience for whatever system you may have.</p>
<p><strong>USER FRIENDLY, ACCESSIBLE CONTROLS</strong></p>
<p>Navigate the user-friendly interface, and you can adjust the CO2 calibration, pump time, and other parameters on the fly. There’s no need to reboot and no need to warmup – it’s as easy as it gets.</p>
<p><strong>ABOUT THE SENSOR</strong></p>
<p>The infrared CO2 sensor utilizes NDIR technology for maximum stability, and has a theoretically unlimited lifespan.  It has no moving parts, no consumables, and is housed in a compact optical cell. The sensor responds to CO2 only.  The sensor is unaffected by high levels of background gases such as nitrogen or oxygen.</p>
<p><strong>WARRANTY STATEMENT</strong></p>
<p>The Model Q41 is backed up with a two-year warranty, twice the industry standard.<br />
Our service team responds quickly to the repair needs of our customers, and repairs and calibrations are conducted in our advanced facility in Massachusetts.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Q40 Rackmount-2U O2 Analyzer</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/q40rack-mount-2u-o2-analyzer/</link>
		
		<dc:creator><![CDATA[Scott Mckeown]]></dc:creator>
		<pubDate>Thu, 22 Aug 2024 17:26:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.quantekinstruments.com/?post_type=product&#038;p=4219</guid>

					<description><![CDATA[The Quantek Model Q40 is our next generation rackmount O2 analyzer. Use it for process systems, inline testing, along with many other types of applications.

This microprocessor-controlled instrument features onboard data collection, a TFT full color screen, built in analog output (0-5V), and EasyCal calibration using the touchpad.  Additionally, it can be outfitted with options such as a sample pump, or a 12-hour runtime internal battery.

Readings can be exported to USB thumb drive as CSV file for further processing. The Q40 comes with a power supply, thumb drive, and consumable accessories.]]></description>
										<content:encoded><![CDATA[<p><strong>NEXT GENERATION TECHNOLOGY</strong></p>
<p>Introducing the Q40, the next generation of Quantek analyzers. This analyzer utilizes the latest in microprocessor-based sampling, and comes equipped with an advanced TFT display, smart charging, onboard data collection, advanced pump functions, and EasyCal calibration controls.</p>
<p><strong>LONG LIFE, STABLE SENSORS</strong></p>
<p>The Model Q40 incorporates the latest fast response O2 sensor, which allows results to be obtained in 15-25 seconds for rapid spot checks. The oxygen sensor is rated for 5 years of life, which is far better than the competition. Other analyzers utilize cheap oxygen sensors which may last 18-24 months.</p>
<p><strong>EASY SAMPLING METHOD</strong></p>
<p>The Q40 series sample inlet and outlet are located on the rear panel for ease of access.  By default, both fittings are 1/8” stainless steel Swagelok.  Other inlet/outlet configurations are available upon request.  Some examples include standard luer fittings, ¼” Swagelok fittings, or a sample probe.  We can recommend or customize fittings to give the most seamless sampling experience for whatever system you may have.</p>
<p><strong>USER FRIENDLY, ACCESSIBLE CONTROLS</strong></p>
<p>Navigate the user-friendly interface, and you can adjust the oxygen calibration, pump time, and other parameters on the fly.  There’s no need to reboot and no need to warmup – it’s as easy as it gets.</p>
<p><strong>ABOUT THE SENSOR</strong></p>
<p>The electrochemical O2 sensor life is typically 4-5 years, unlike other analyzers with an electrochemical sensor that last 1-2 years. When required, replacement is easy and inexpensive.  The sensor is unaffected by high levels of background gases such as nitrogen or CO<sub>2</sub>.</p>
<p><strong>WARRANTY STATEMENT</strong></p>
<p>The Model Q40 is backed up with a two-year warranty, twice the industry standard.<br />
Our service team responds quickly to the repair needs of our customers, and repairs and calibrations are conducted in our advanced facility in Massachusetts.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Q31 Benchtop CO2 Analyzer</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/q31-benchtop-co2-analyzer/</link>
		
		<dc:creator><![CDATA[Scott Mckeown]]></dc:creator>
		<pubDate>Tue, 06 Aug 2024 12:56:31 +0000</pubDate>
				<guid isPermaLink="false">https://www.quantekinstruments.com/?post_type=product&#038;p=4211</guid>

					<description><![CDATA[The Quantek Model Q31 is our next generation portable CO2 analyzer. Use it for incubator testing, along with many other types of applications.

This microprocessor-controlled instrument features onboard data collection, a hold function (the reading freezes on the screen when the test is complete), a 12-hour internal battery, a TFT full color screen, and EasyCal calibration using the touchpad.

Readings can be exported to a USB thumbdrive (included) as a CSV file for further processing. The Q21 comes with battery pack, internal pump, carry case, and accessories.]]></description>
										<content:encoded><![CDATA[<p><strong>NEXT GENERATION TECHNOLOGY</strong></p>
<p>Introducing the Q31, the next generation of Quantek analyzers. This analyzer utilizes the latest in microprocessor-based sampling, and comes equipped with an advanced TFT display, smart charging, onboard data collection, advanced pump functions, and EasyCal calibration controls.</p>
<p><strong>LONG LIFE, STABLE SENSORS</strong></p>
<p>The Model Q31 incorporates the latest fast response CO2 sensor, which allows results to be obtained in 15-25 seconds for rapid spot checks.  The CO2 detector is a dual wavelength NDIR sensor with a theoretically unlimited lifespan.</p>
<p><strong>EASY SAMPLING METHOD</strong></p>
<p>The sample probe connects to a barbed inlet fitting that is attached to the analyzer.  Extra probe tubing is included with each analyzer for easy exchange in case of contamination or damage.  The probe is tipped with a liquid blocking filter and tri-beveled, non-coring needle. The filter will block liquid and particle intake into the analyzer, and the needle is specially designed to prevent plugging.  Extra tubing is provided for incubator or other process applications.</p>
<p><strong>USER FRIENDLY, ACCESSIBLE CONTROLS</strong></p>
<p>Navigate the user-friendly interface, and you can adjust the CO2 calibration, pump time, and other parameters on the fly. There’s no need to reboot and no need to warmup – it’s as easy as it gets.</p>
<p><strong>ABOUT THE SENSOR</strong></p>
<p>The infrared CO2 sensor utilizes NDIR technology for maximum stability, and has a theoretically unlimited lifespan. Its ultra-low power consumption allows for 10-14 hours of runtime for the analyzer before recharging is required.<br />
It has no moving parts, no consumables, and is housed in a compact optical cell. The sensor responds to CO2 only.  The sensor is unaffected by high levels of background gases such as nitrogen or oxygen.</p>
<p><strong>WARRANTY STATEMENT</strong></p>
<p>The Model Q31 is backed up with a two-year warranty, twice the industry standard.<br />
Our service team responds quickly to the repair needs of our customers, and repairs and calibrations are conducted in our advanced facility in Massachusetts.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Model 902P O2 / CO2 Analyzer</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/o2-co2-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 16:32:53 +0000</pubDate>
				<guid isPermaLink="false">https://quantekinstruments.com/product/o2-co2-analyzer/</guid>

					<description><![CDATA[O2 and CO2 Analyzer for research processes, gas blending, biotech, and other systems.
The Model 902P O2 CO2 analyzer measures 0 to 100% O2 concentrations, and 0-1% to 0-100% CO2 vol/vol full scale, in a variety of process, research, and biotech applications. Options include internal sample pump, battery operation, analog outputs, and complete data collection option (including analysis software for long term experiments).]]></description>
										<content:encoded><![CDATA[<h2>EASE OF SAMPLING</h2>
<p>Sample flows into the analyzer through the front panel fitting, and vents out through an exhaust port on the back panel. The exhaust port can also be equipped with a connectible luer fit connection, should you wish to keep your system closed. The recommended flow rate is 50 cc/min, although the analyzer can accept 10 to 1000 cc/min without adversely affecting the response time or readings.</p>
<p>The sensor operates at atmospheric pressure, and a flow bypass in the internal plumbing arrangement allows for excess pressure to vent. This allows for higher acceptable flow rates, without affecting the accuracy of your measurements.</p>
<h2>NO SOURCE OF FLOW OR POSITIVE PRESSURE? NO PROBLEM.</h2>
<p>For systems where a source of sample flow (or positive pressure) is not available, the Model 902P can be equipped with an optional internal miniature diaphragm pump with an on-off switch on the front panel. This pump draws about 5 cc/second from your chamber, experiment, room, or system.</p>
<p>The pump is electronically controlled to operate only when sampling, and can be adjusted to run for 2-12 seconds per button press. Furthermore, if you equip the analyzer with the pump, you can still introduce sample directly into the inlet fitting without pressurizing the analyzer or affecting your readings.</p>
<p>The pump is electronically timed to draw in the amount of sample required for the analysis, and then turns itself off after the pre-set sampling time (2 to 12 seconds). Advanced optional pump controls include two mode pump switch (for continuous pump or timed operation), cycling pump (set to run for x seconds on, x seconds off), or concentration activated pump (pump turns on when O2 or CO2 goes above or below preset limit).</p>
<h2>INTERNAL, USER-REPLACEABLE MOISTURE TRAP FILTER</h2>
<p>While the sample introduced should be clean and dry (non-condensing), should moisture enter the analyzer, the Model 902P is equipped with an internal moisture trap filter. This provides a last barrier of protection, and is user-replaceable (we provide spares).</p>
<h2>ABOUT THE CO2 SENSOR</h2>
<p>The Model 902P uses a solid-state infrared CO2 sensor which has no moving parts, a compact optical cell, and microprocessor-based calibration factors using a 6th order polynomial equation to linearize the full range measurement up to 100%. Infrared CO2 measurements are inherently non-linear, especially over a high range of concentrations. The math algorithm used in the 902P yields more accurate results over a much wider range of concentrations than other methods. The expected life of the CO2 sensor is theoretically unlimited, as it contains no moving parts.</p>
<p>The Model 902P CO2 sensor combines cutting edge 32-bit digital signal processing with the solid reliability, compact size and state of the art microprocessor technology that makes this full-featured CO2 measurement system less complex and more robust than other instrumentation.</p>
<h2>ABOUT THE O2 SENSOR</h2>
<p>The Model 902P uses a long-life heavy duty electrochemical O2 sensor, with an expected lifetime of 5 years. Other electrochemical O2 sensors have an expected life of 1-2 years.</p>
<h2>BACKGROUND GAS</h2>
<p>Both the CO2 and O2 sensors are unaffected by high levels of background gases such as nitrogen. The O2 sensor is unaffected by high levels of CO2, and vice versa.</p>
<h2>ABOUT THE MICROPROCESSOR/ELECTRONICS</h2>
<p>Micro-processor based electronics provide sensor signal processing, battery charging, pump timing and on/off control for high accuracy and reliability with minimal component use and reduced size and cost.</p>
<h2>ABOUT THE OPTIONAL BATTERY</h2>
<p>With its low power requirement, the Model 902P can be operated with an optional battery for those applications where AC power is not readily available, or for convenience if spot checking samples at different locations. A totally sealed, long-life internal 12 Vdc battery accepts a full or partial charging cycle and will operate the unit for up to 8 hours. The charger module plugs into a standard 110-240V outlet for charging or continuous operation. Alternatively, the unit can be powered from an external 12-24 Vdc source.</p>
<h2>ABOUT THE WARRANTY</h2>
<p>The Model 902P is backed it up with a two year warranty, twice the industry standard. The advanced design allows an output requiring less frequent calibration. It provides a stable, drift-free linearized voltage or current output that is much less susceptible to external electro-magnetic interference than conventional analog electronics.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Model 906 CO2 Analyzer for Process &#038; Research</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/co2-analyzer-for-process-research/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 16:32:53 +0000</pubDate>
				<guid isPermaLink="false">https://quantekinstruments.com/product/co2-analyzer-for-process-research/</guid>

					<description><![CDATA[The Quantek Model 906 CO2 Analyzer is designed for continuous or spot measurement and analysis of carbon dioxide levels.
Analysis ranges of 0-5,000ppm, 0-10,000ppm, 0-25,000ppm, 0-20%, or 0-100% vol/vol.
Simply introduce your sample gas flow into the inlet of the Model 906 CO2 analyzer, and see results on the LCD within 15-20 seconds. The inlet accepts a flow rate of 5cc/min to 1000 cc/min. If you don’t have a source of flow or positive pressure, the analyzer can be equipped with an internal pump to draw in sample gas for analysis.]]></description>
										<content:encoded><![CDATA[<h2>CO2 SENSOR – BASICS</h2>
<p>The sensor design is compact, has a low internal volume and requires only a low sample flow of about 5 to 1000 cc/min. Our market leading CO2 sensor uses the latest in dual-wavelength NDIR measurement principles, reducing drift and allowing for results in as little as 10-15 seconds. While the sample introduced should be clean and dry (non-condensing), should moisture enter the analyzer, the Model 906 is equipped with an internal moisture trap filter. This provides a last barrier of protection, and is user-replaceable (we provide spares).</p>
<h2>CO2 SENSOR – DETAILS</h2>
<p>The Model 906 uses a solid-state infrared sensor which has no moving parts, a compact optical cell, and microprocessor-based calibration factors using a 6th order polynomial equation to linearize the full range measurement up to 100%. Infrared CO2 measurements are inherently non-linear, especially over a high range of concentrations. The math algorithm used in the 906 yields more accurate measurements over a much wider range of concentrations than other methods.</p>
<h2>EASE OF SAMPLING</h2>
<p>Sample gas flows into the analyzer through the front panel fitting, and vents out through an exhaust port on the back panel. The exhaust port can also be equipped with a connectible luer fit connection, should you wish to keep your system closed.</p>
<p>The sensor operates at atmospheric pressure, and a flow bypass in the internal plumbing arrangement allows for excess pressure to vent. This allows for higher acceptable flow rates, without affecting the accuracy of your measurements.</p>
<h2>DATA COLLECTION OPTIONS</h2>
<p>If you have your own data acquisition equipment already, we can equip the Model 906 with a Vdc or 4-20mA output on the back – linear to the concentration displayed on the LCD.</p>
<p>If you do not have data acquisition equipment, we offer a complete data logging solution. This solution allows you to record readings at intervals from 1 second to 18 hours, and comes complete with graphing/analysis software. The results can then be exported via .csv or .txt files to other software for analysis.</p>
<h2>ABOUT THE OPTIONAL BATTERY</h2>
<p>With its low power requirement, the Model 906 can be operated with an optional battery for those applications where AC power is not readily available, or for convenience if spot checking samples at different locations. A totally sealed, long-life internal 12 Vdc battery accepts a full or partial charging cycle and will operate the unit for up to 8 hours. The charger module plugs into any international 100-240V outlet, for charging or continuous operation. The analyzer need not be turned off during the charge cycle.</p>
<h2>ABOUT THE WARRANTY</h2>
<p>The Model 906 is backed it up with a two year warranty, twice the industry standard. The advanced design allows an output requiring less frequent calibration. It provides a stable, drift-free linearized voltage or current output that is much less susceptible to external electro-magnetic interference than conventional analog electronics.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Model 201 Portable oxygen analyzer</title>
		<link>https://quantekinstruments.maxdroplet8.maxburst.dev/product/portable-oxygen-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 16:32:53 +0000</pubDate>
				<guid isPermaLink="false">https://quantekinstruments.com/product/portable-oxygen-analyzer/</guid>

					<description><![CDATA[The Quantek Model 201 is a portable oxygen analyzer used primarily for the measurement of O2 concentration in gas flows, chambers, or gas flushed hoods (such as glove boxes).
The analyzer comes with both an “open faced” fitting and a T-fitting, allowing it to be used for analyzing gas flows, or set in chambers where oxygen levels need to be monitored.

The sensor operation is not sample flow dependent, and accurate results are obtained on both static and flowing samples.]]></description>
										<content:encoded><![CDATA[<h2>HEAVY DUTY, LONG-LIFE SENSOR</h2>
<p>The sensor is a proprietary electrochemical type with a measurement range of 0.0 to 100%. Excellent linearity through the entire range allows a calibration with one set point using room air. It is unaffected by high levels of background gases such as nitrogen or carbon dioxide. The Model 201 can be used for applications where the oxygen level is very high (50 to 100%), without overloading the sensor. It is unaffected by trace hydrocarbons or high levels of CO2, which can poison other types of sensors, and operates independent of flow rate.</p>
<h2>BATTERY OR AC OPERATION</h2>
<p>The Model 201 comes in two configurations – pick either AA battery operation, or AC power operation to allow for 100% uptime.</p>
]]></content:encoded>
					
		
		
			</item>